• ChemTec Adjustable Flow Monitor Series LCA

ChemTec Adjustable Flow Monitor Series LCA

$143.00143USD
Are you buying in volume? Are you an OEM? Are you a reseller? Be sure to contact FLW directly for your special pricing.  
Quantity:
Availability:
PART NUMBER:
LCA
Shipping Weight:
1.00 LBS
Shipping:
Calculated at checkout

Description

Features:
  • Adjustable
  • Confirms: Normal flow conditions
  • Senses: High flow or low flow conditions
  • Output: Switch contact
  • Economical
Applications:
  • Machine lubrication
  • Process flows
  • Cooling systems
  • Water treatment systems
Operations:

When flow is increased, the magnetic piston is forced against a bias spring. As the magnet comes near the adjustable reed switch it actuates, indicating proper flow. When flow decreases the spring forces the piston in the opposite direction deactuating the reed switch an indicating a reduced or no flow situation.
  • All models field adjustable
  • Deactuation (decreasing flow) averages 40% less than actuation (increasing flow)
  • Repeatability ± 2%
  • Correction must be made for attitudes other than horizontal
  • Unit will pass greater flows

Product Specifications

General Specifications

ModelMaximum Working Pressure PSIG (BARG)Wetted Parts
LCA-250P100 (6.89)PVC, Epoxy, 316SS
LCA-250-B1500 (103.42)Brass, Epoxy, 316SS
LCA-250-S3000 (206.84)316SS, Epoxy
LCA-375P100 (6.89)PVC, Epoxy, 316SS
LCA-375-B1500 (103.42)Brass, Epoxy, 316SS
LCA-375-S3000 (206.84)316SS, Epoxy
LCA-500P100 (6.89)PVC, Epoxy, 316SS
LCA-500-B1500 (103.42)Brass, Epoxy, 316SS
LCA-500-S3000 (206.84)316SS, Epoxy
LCA-750P100 (6.89)PVC, Epoxy, 316SS
LCA-700-B1500 (103.42)Brass, Epoxy, 316SS
LCA-700-S3000 (206.84)316SS, Epoxy
Calibration Range
ModelAdjustable Range
Increasing Flow Water LPM (GPM)
Factory Preset
Decreasing Flow Water LPM (GPM)
Inlet/Outlet FNPT Port
LCA-2500.38 - 15.1
(0.10 - 4.00)
-10 0.38 (0.10)
-20 9.46 (2.50)
-30 11.46 (3.00)
1/4"
LCA-3751.89 - 15.1
(0.50 - 4.00)
-10 1.89 (0.50)
-20 9.46 (2.50)
-30 11.36 (3.00)
3/8"
LCA-5001.89 - 37.9
(0.50 - 10.00)
-10 1.89 (0.50)
-20 18.93 (5.00)
-30 28.39 (7.50)
1/2"
LCA-7503.79 - 56.8
(1.00 - 15.00)
-10 3.79 (1.00)
-20 18.93 (5.00)
-30 28.39 (7.50)
1/2"
Pressure Loss Table
ModelWater Flow Rate LPM (GPM)ΔP BARD (PSID)
LCA-250/375   
Minimum0.38 (0.10)0.34 (0.5)
Maximum15.14 (4.0)0.21 (3.0)
LCA-500   
Minimum1.89 (0.5)0.069 (0.1)
Maximum37.85 (10.0)0.689 (10.0) 
LCA-750   
Minimum3.79 (1.0)0.10 (1.5)
Maximum56.8 (15.0)0.62 (9.0)

Literature & Docs