• Partlow MIC 2000 Process Controller

Partlow MIC 2000 Process Controller

Contact FLW for help with configuration.

USD
Are you buying in volume? Are you an OEM? Are you a reseller? Be sure to contact FLW directly for your special pricing.  
Quantity:
Availability:
PART NUMBER:
MIC 2000
Shipping Weight:
3.00 LBS

Description

The MIC 2000 is a single loop, ¼ DIN controller capable of controlling a variety of processes ranging from simple on/off to dual 4-20mA output with full PID. Inputs include thermocouple, RTD, millivolt, volt, and milliamp.

Standard features include: isolated process input, setpoint and output limits, and .56 inch high LEDs. It will display programming of process deviation and setpoint, of percent output, and scaling with decimal point positioning.

Optional features include: up to thouree relay outputs, thouree types of alarms, remote setpoint input, electric motor modulation, RS-485 communications and process value retransmission output as well as restricted security access. Access to configuration parameters and setpoint may be restricted by using the instrument's security-access mode.

Applications:

Ideal for temperature control applications requiring a value-priced, user-friendly, versatile and full featured temperature controller.

Industries:
  • Industrial and lab ovens/furnaces, plastics and thermal forming
  • Form/Fill and seal
  • Packaging applications
  • And any others where low costs, smaller size and unmatched connectivity are critical requirements.
Features/Benefits:
  • Single, 4-digit, 0.56" LED display
  • ¼ DIN panel mount
  • Universal Input for thermocouple, RTD DC linear V, DC linear mA/mV user-selectable
  • Up to 3 outputs; relay, SSR driver, 4-20mA
  • Process or deviation/band alarm functions
  • ON/OFF, position proportioning, PID Control
  • Optional RS-485 serial communications
  • Program security

Product Specifications

Inputs

Thermocouple types:J, K, T, R, S, E, B, N, and C
RTD:100 ohm platinum (.00385 Ohm/Ohm/C)
Volts:0 to 5VDC, 1 to 5 VDC
Millivolts:0 to 25mVDC, 0 to 50mVDC, 10 to 50mVDC
Milliamps:0 to 20 or 4 to 20mADC, accommodated via the addition of a shunt resistor
Remote Setpoint:0 to 5VDC, 1 to 5 VDC
Sensor Fault Detection:Displays Hi or Lo for thermocouple or RTD inputs (10% above or below range) and sensor break, SnSr. On/Off outputs go off, proportional outputs go to 0%. Sensor fault detection is not functional for 0 to 5VDC or 0 to 20mADC
Outputs
Relay:SPST
115VAC: 5.0 A Resistive; 1/8HP or 250VA
230VAC: 2.5 A Resistive; 1/8HP or 250VA
SSR Driver:Open collector output
Short circuit protected at 100mA maximum
Provides 4VDC at 20mA or 3VDC at 40mA
Current Output:0-20 or 4-20 mADC into 650 ohms maximum

Literature & Docs