Description Specifications Literature Description Blancett Floclean Sanitary Turbine Flow Meters (now Badger Meter) were developed for use in the food, beverage and pharmaceutical industries. The 316L stainless steel construction provides a durable and cost efficient flow measurement system that offers excellent accuracy and repeatability. The Floclean uses the most up-to-date polishing technology on all internal components and all materials comply with FDA requirements. Floclean B16D Series meters have removable thrust bearings for ease of cleaning and inspection, and meet the requirements of 3-A Sanitary Standard number 28-04 for use in clean-out-of-place (COP) and sanitize-out-of-place (SOP) applications and carry the 3-A Sanitary symbol. The Floclean output signal is a sine-wave that is proportional to volumetric flow. With optional Blancett electronics, Floclean provides local flow rate and volume totalization and interfaces with most displays, PLCs and computers.InstallationInstall the flow meter with the flow arrow, which is etched on the exterior of the meter body, pointing in the direction of fluid flow. Install the meter horizontally with the magnetic pickup facing upward. For optimum performance, the flow meter should be installed with a minimum of 10 diameters upstream straight pipe length and 5 diameters downstream straight pipe length. State of California Proposition 65 WARNINGCancer and Reproductive Harm - www.P65Warnings.ca.gov. Product Specifications Clamp Size x Bore Size2-1/2 in. x 2 in.Maximum Pressure1000 PSIFlow Rate40-400 GPM150-1500 LPMK-Factor52 Pulses/Gal Literature & Docs Data Sheet User Manual Brochure Accessories