Mensor Temperature Dry-Well Calibrator CTD9300-165
Are you buying in volume? Are you an OEM? Are you a reseller? Be sure to contact FLW directly for your special pricing.
Description
Whether in laboratories, workshops or on site, these temperature dry-well calibrators can meet any calibration requirement. As an option, all instruments are available with an integrated measuring instrument. This enables the measurement of resistances, thermoelectric voltages and also current signals (from thermometers with a 0/4 ... 20 mA transmitter) and their direct display in °C.
Using our calibration software and a laptop computer, fully automatic calibrations of electrical thermometers can be carried out anywhere. It is also possible to retrofit the integrable measuring instrument into existing calibrators.
Applications:
Using our calibration software and a laptop computer, fully automatic calibrations of electrical thermometers can be carried out anywhere. It is also possible to retrofit the integrable measuring instrument into existing calibrators.
Applications:
- Bio and pharmaceutical industries
- Food industry
- Demanding on-site calibrations
- Measurement and control laboratories in the chemical industry
- Power plants and plant construction
- Easy operation via intuitive, user-friendly menus
- Large, easy-to-read display
- Short response times due to optimised control
- Improved accuracy due to homogeneous block temperature
Product Specifications
Display | CTD9300-650 | CTD9300-165 |
---|---|---|
Temperature Range: | 40 to 650 °C (104 to 1,202 °F) | -35 to +165 °C (-31 to +329 °F) |
Accuracy: | ±0.3 K at 300 °C (572 °F) | ±0.1 K at -30 °C (-22 °F) |
±0.6 K at 650 °C (1,202 °F) | ±0.16 K at 165 °C (329 °F) | |
Stability: | ±0.03 K at 100 °C (212 °F) | ±0.01 to 0.02 at 165 °C (329 °F) |
±0.09 K at 650 °C (1,202 °F) | ||
Resolution: | 0.01 K | |
Axial Homogeneity: | 0.4 K | 0.06 K |
Radial Homogeneity: | dependent on temperature, temperature probes and their quantity | dependent on temperature, temperature probes and their quantity |
Heating Time: | 30 min from 20 °C to 650 °C | 12 min from 20 °C to 165 °C |
(from 68 °F to 1,202 °F) | (from 68 °F to 329 °F) | |
Cooling Time: | 80 min from 650 °C to 100 °C | 7 min from +20 °C to -20 °C |
(from 1,202 °F to 212 °F) | (from +68 °F to -4 °F) | |
Stabilization Time: | dependent on temperature and temperature probe | |
Metal Block Insertion Depth: | 150 mm (5.91 in) | 150 mm (5.91 in) |
Insert Dimensions: | ∅ 28 x 150 mm (1.1 x 5.91 in) | ∅ 28 x 150 mm (1.1 x 5.91 in) |
Block Material: | Brass | Aluminium |
Power Supply: | AC 230 (115) V, 50/60 Hz | AC 100 to 240 V, 50/60 Hz |
Power Consumption: | 1,000 W | 400 W |
Power Cord: | for Europe, 230 V | |
Interface: | RS-232 | RS-232 |