Loading... Please wait...
  • Contact Us
  • My Account

  • Alnor EBT Balometer Capture Hood EBT731
  • Alnor EBT Balometer Capture Hood EBT731
  • Alnor EBT Balometer Capture Hood EBT731

Alnor EBT Balometer Capture Hood EBT731

$3,165.00

Description

The TSI Alnor EBT731 Balometer® Capture Hood is an electronic air balancing multipurpose instrument mainly used to take direct air volume readings at diffusers and grilles. The EBT731 features a detachable micromanometer which can be used with optional probes for increased flexibility in multiple measurement applications.

The easy-to-use EBT731 is a lightweight and ergonomically designed capture hood kit which conveniently provides multiple measurement tools in one package. The EBT731 Balometer Capture Hood provides you the capability to produce energy efficient environments while staying within guidelines and regulations for ventilation systems.

Included Items
  • 2 ft x 2 ft. (610 mm x 610 mm) air capture hood/frame/base
  • Manometer with carrying case
  • (4) AA size rechargeable NiMH batteries
  • Multi-country AC adapter
  • 18in. (46 cm) Pitot probe
  • (2) Static Pressure probes
  • 16 ft (4.8 m) Neoprene tubing
  • Wheeled luggage-style carrying case
  • NIST traceable calibration certification
  • Downloading software
  • USB interface cable
  • Manual

Product Specifications

Velocity Range

Pitot probes:25 to 15,500 ft./min (0.125 to 78 m/s)
Air flow probe:25 to 5,000 ft./min (0.125 to 25 m/s)
Velocity matrix:25 to 2,500 ft./min (0.125 to 12.5 m/s)
Accuracy:±3% of reading ±7ft./min (±0.04 m/s) at velocities >50 ft./min (>0.25 m/s)
Units:ft./min, m/s
Resolution:1 ft./min (0.01 m/s)
Pressure
Differential pressure:±15 in. H20 (±3735 Pa); 150 in. H20 (37.5 kPa), maximum safe operating pressure
Absolute pressure:15 to 40 in Hg (356 to 1016 mm Hg)
Accuracy:±2% of reading ±0.0001 in. H20 (±0.025 Pa) static and differential; ±2% of reading absolute
Units:in. H20, in. Hg, Pa, hPa, kPa, mm Hg, cm Hg, mm H20, cm H20
Resolution:0.00001 in. H20 (0.001 Pa) static and differential; 0.01 in. Hg (1 mm Hg) absolute
Volume
Range:25 to 2,500 ft.³/min (42 to 4250 m³/h) capture hood, supply and return
Accuracy:±3% of reading ±7 ft.³/min (± m³/h) at flows >50ft.³/m (>80 m³/h)
Units:1 ft.³/min, m³/h, m³/min, l/s
Resolution:1 ft.³/min (1 m³/h)
RH
Range:5 to 95% RH (temperature/RH probe)
Accuracy:±3% RH
Resolution:0.1% RH
Temperature
Sensor in base:40 to 140°F (4.4 to 60°C)
Temperature/RH probe:14 to 140°F (-10 to 60°C)
Accuracy:±0.5°F (±0.3°)
Units:°F, °C
Resolution:0.1°F (0.1°C)

Videos