Description Specifications Literature Description The GO Switch Model 7F has a custom probe length and all the all the features and benefits of the Stroke to GO™ cylinder position sensor product line. Benefits:SPDT 4A contactsInherently Intrinsically Safe-40 DEG C to 221 DEG F operating temperatureInherently weld field immuneNon voltage dependentSingle piece S.S. probeOptional -40 DEG to 400 DEG F high temperatureUnderwater optionOptional LED status indication State of California Proposition 65 WARNINGCancer and Reproductive Harm - www.P65Warnings.ca.gov. Product Specifications Product SpecificationsModel:(7F) - Custom Probe Length Probe Length: 1.000" Contact Form: SPDT (Form C) without LED Sensing Range: Standard sensing approximately .090" end sensing (Recommended air gap .015" - .040") Outlet Position: Side entry 360° adjustable with 1/2" NPT conduit hub Enclosure Material: Stainless steel (rated 3,000psi operating) (3 to 1 safety factor applies to standard probe lengths) Area Classification: HiTemp to 400°F Wiring Options: Hi-Temp Leads - 18 gauge, Teflon™ insulated 36" Literature & Docs Product Specifications Accessories