• GPI Flomec Insertion Ultrasonic Flowmeter QS200

GPI Flomec QS200 Insertion Ultrasonic Flowmeter

$382.00
Are you buying in volume? Are you an OEM? Are you a reseller? Be sure to contact FLW directly for your special pricing.  
Quantity:
Availability:
PART NUMBER:
QS200
Shipping Weight:
1.00 LBS
Shipping:

FREE Ground Shipping

Description

The QS200 Insertion Ultrasonic Flowmeter provides an accurate reading of liquid flow rate and accumulated flow. Designed to support commercial irrigation applications, the QS200 is available in five pipe sizes, 1 to 4 in.
The QS200 ultrasonic insert is available with a PVC tee or as an "insert retrofit" for replacement of existing paddlewheel flow sensors.

Features / Benefits
  • Low-cost, effective and easy installation
  • No moving mechanical parts (low-maintenance)
  • Simple two-wire connector (for power and pulse)
  • Compatible with irrigation controllers (common name brands)
  • High accuracy: +/-2.0% of reading (compared to full scale accuracy)
  • Provides extended leak detection down to 0.1 fps (0.03 m/s)
  • LED light indicators: (green for power and amber for pulse)
  • Patent pending design
  • Ideal for clean water flow measurement
  • External wiring: (direct burial wire)
Insert Description
Designed for above and below grade applications, such as irrigation, municipal and underground monitoring where the flow rates are between 0.1 to 15 fps (0.03 to 4.57 m/s) and temperatures are below 140°F (60°C). QS200 inserts are supplied with two single conductors, 18 AWG solid copper wire leads that are 36 inches (914.4 mm) in length with UL Style 116666 direct burial insulation.

Product Specifications

General Specifications

Tee Housing Material: Schedule 80 PVC
Insert Wetted Materials: Body: PPS (Ryton R-4)
Sensor: PEI (Ultem 1000)
O-Ring: EPDM
Temperature Rating:
Operating: 32°F to 140°F (0°C to 60°C)
Storage: -20°F to 160°F (-29°C to 71°C)
Flow Range: 0.1 to 15 fps (0.03 to 4.57 m/s)
Accuracy: Typically +/-2% of reading
Operating Pressure: 150 psi @ 73°F (10 bar @ 23°C)
100 psi @ 140°F (7 bar @ 60°C)
Transducer Excitation: Supply Voltage: 7.5V (dc) min. to 36V (dc) max
Quiescent Current: 200 μA (typical)
Output Frequency: 0 to 100 Hz
Output Pulse Width: 4 ms
Electrical Cable for
Insert Electronics:
36 inches (914.4 mm) of 18 AWG, solid copper, "Direct Burial" (UL 493 & 83)
Flow Insert Selection Chart
Flowmeter Model Pipe Size Operating
Range (Min.)
Operating
Range (Max.)
QS200-10 1 in. 0.22 GPM
(0.83 L/min)
0.1 ft/sec
33 GPM
(124.92 L/min)
15 ft/sec
QS200-15 1.5 in. 0.55 GPM
(2.08 L/min)
0.1 ft/sec
82 GPM
(310.41 L/min)
15 ft/sec
QS200-20 2 in. 0.92 GPM
(3.48 L/min)
0.1 ft/sec
138 GPM
(522.39 L/min)
15 ft/sec
QS200-30 3 in. 2.06 GPM
(7.80 L/min)
0.1 ft/sec
309 GPM
(1169.70 L/min)
15 ft/sec
QS200-40 4 in. 3.58 GPM
(13.55 L/min)
0.1 ft/sec
537 GPM
(2032.78 L/min)
15 ft/sec
QS200 Insert only