• Mensor Temperature Dry-Well Calibrator CTD9100-165
  • Mensor Temperature Dry-Well Calibrator CTD9100-165

Mensor Temperature Dry-Well Calibrator CTD9100-165

Are you buying in volume? Are you an OEM? Are you a reseller? Be sure to contact FLW directly for your special pricing.  
Quantity:
Availability:
PART NUMBER:
CTD9100-165
Shipping Weight:
25.00 LBS

Description

Nowadays, fast and simple testing of thermometers is a "must" when it comes to the operational reliability of machines and plants. The portable calibrators of the CTD9100 family are particularly suited to local calibration tasks. They are extremely userfriendly. Due to their compact design and their low weight, the instruments can be taken and used almost anywhere.

The CTD9100-165 calibrators work with Peltier elements and can therefore reach test temperatures below ambient temperature. Due to the feature of active cooling, they are frequently used in the bio-pharmaceutical and food industries. calibrator has an enlarged insert with ∅ 60 mm. Thus it is possible to calibrate several temperature sensors simultaneously or to calibrate thermometers with various diameters without having to change the sleeve.

Applications:
  • Easy on-site calibration
  • Power generation
  • Measurement and control laboratories
  • Machine building
Special Features:
  • Various temperature ranges
  • Measurement uncertainties from 0.15 ... 0.8 K
  • Compact design
  • Simple operation

Product Specifications

General Specifications

Model CTD9100-COOLModel CTD9100-165
Temperature range:-55 ... +200 °C (-67 ... +392 °F)-35 ... +165 °C (-31 ... +329 °F)
Accuracy:0.15 ... 0.3 K0.15 ... 0.25 K
Stability:±0.05 K±0.05 K
Resolution:0.01 up to 100 °C, then 0.1 (0.01 up to 212 °F, then 0.1)0.01 up to 100 °C, then 0.1 (0.01 up to 212 °F, then 0.1)
Axial Homogeneity Temperature Distribution:< 0.04 K at 200 °C (392 °F)< 0.04 K at 100 °C (212 °F)
0.06 K up to 165 °C (329 °F)
Radial Homogeneity Temperature Distribution:dependent on temperature, temperature probes and their quantitydependent on temperature, temperature probes and their quantity
Heating time:approx. 10 min from 20 to 200 °C (from 68 °F to 392 °F)approx. 25 min from 20 to 165 °C (X approx. 35 min) (from 68 °F to 329 °F)
Cooling time:approx. 10 min from +20 to -20 °C (from 68 °F to -4 °F)approx. 15 min from +20 to -20 °C (X approx. 35 min)(from 68 °F to -4 °F)
Stabilization time:dependent on temperature and temperature probedependent on temperature and temperature probe