Description Specifications Literature Description The Ashcroft® ZT12 high purity transmitter is designed for use in UHP gas and fluidic delivery systems. Its compact design allows for high density installations, while the 316L electropolished stainless steel wetted material allows for rapid dry-down times.Key FeaturesUltra-stable CVD sensing technologyRanges from vacuum to 3,000 PSI, compound, Absolute ranges available4-20mA outputLow internal volume (0.9cm³)20RA (0.5µm) or optional 7RA (0.18µm)Excellent EMI/RFI resistanceClass 100 cleanroom packaged and double baggedCE and UKCA approvedRoHS compliantApplicationsIndustrialHigh Purity Gas Delivery SystemsGas SticksProcess Gas AnalyzersPurge and Exhaust Gas Systems State of California Proposition 65 WARNINGCancer and Reproductive Harm - www.P65Warnings.ca.gov. Product Specifications Product SpecificationsAccuracy:±0.25% of span @ 73.4 °F (23 °C) Accuracy includes the effects of linearity, hysteresis and repeatabilityStability:±0.25% Span/yearOutput Signal:4-20 mA (2 Wire)Pressure Ranges:Vacuum & 45 PSI to Vacuum & 3,000 PSI, Gauge: 0-45 PSI to 0-3,000 PSI, Absolute: 0-45 PSI to 0-3,000 PSIProcess Connection:9/16-18 UNF Male/Female fixed, swivel or flow through (compatible with 1/4 VCR® fitting)Wetted Material:316L Stainless SteelNon-Wetted Materials:304 Stainless Steel, PBTIngress Rating:IP65 (with mating connector installed) Literature & Docs Data Sheet Accessories